| FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZASG125M7Y1B | FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZASG140M7Y1B | FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZASG100M7Y1B (Archived) | FBA50A2VEB / FBA50A2VEB / RZASG100M7Y1B (Archived) | ||||
|---|---|---|---|---|---|---|---|
| Unité extérieure | RZASG125M7Y1B | RZASG140M7Y1B | RZASG100M7Y1B | RZASG100M7Y1B | |||
| Puissance frigorifique | Nom. | kW | 12.1 | 13.4 | 9.50 | 9.50 | |
| Puissance calorifique | Nom. | kW | 13.5 | 15.5 | 10.8 | 10.8 | |
| Rafraîchissement des locaux | Puissance | Pdesign | kW | 12.1 | 13.4 | 9.50 | 9.50 |
| SEER | 8.59 | 9.67 | 5.31 | 5.38 | |||
| Consommation d’énergie annuelle | kWh/a | 845 | 832 | 626 | 618 | ||
| Chauffage des locaux (climat tempéré) | Puissance | Pdesign | kW | 6.00 | 7.80 | 6.00 | 6.00 |
| SCOP/A | 5.09 | 5.62 | 3.80 | 3.80 | |||
| Consommation d’énergie annuelle | kWh/a | 1650 | 1943 | 2211 | 2211 | ||
| Remarques | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (1) - Les puissances frigorifiques nom. sont basées sur les valeurs suivantes : température intérieure : 27 °CBS, 19 °CBH ; température extérieure : 35°C BS ; longueur équivalente de tuyauterie de réfrigérant : 5 m, dénivellation : 0 m. | (1) - Les puissances frigorifiques nom. sont basées sur les valeurs suivantes : température intérieure : 27 °CBS, 19 °CBH ; température extérieure : 35°C BS ; longueur équivalente de tuyauterie de réfrigérant : 5 m, dénivellation : 0 m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| Rafraîchissement des locaux | Classe d’efficacité énergétique | A | A | ||||
| Chauffage des locaux (climat tempéré) | Classe d’efficacité énergétique | A | A | ||||