| SEHVX20AAW | SEHVX32AAW | SEHVX40AAW | SEHVX64AAW | ||||
|---|---|---|---|---|---|---|---|
| Casing | Colour | Daikin White | Daikin White | Daikin White | Daikin White | ||
| Material | Polyester painted galvanised steel plate | Polyester painted galvanised steel plate | Polyester painted galvanised steel plate | Polyester painted galvanised steel plate | |||
| Dimensions | Unit | Height | mm | 1573 | 1573 | 1573 | 1573 |
| Width | mm | 766 | 766 | 766 | 766 | ||
| Depth | mm | 396 | 396 | 396 | 396 | ||
| Weight | Unit | kg | 60 | 62 | 64 | 66 | |
| Refrigerant | Type | R-410A | R-410A | R-410A | R-410A | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | |||
| Sound power level | Nom. | dBA | 63 | 63 | 66 | 66 | |
| Power supply | Name | W1 | W1 | W1 | W1 | ||
| Phase | 3N~ | 3N~ | 3N~ | 3N~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | ||
| Voltage | V | 400 | 400 | 400 | 400 | ||
| Notes | (1) - Including piping + PHE; excluding expansion vessel | (1) - Including piping + PHE; excluding expansion vessel | (1) - Including piping + PHE; excluding expansion vessel | (1) - Including piping + PHE; excluding expansion vessel | |||
| (2) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (2) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (2) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (2) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | ||||
| (3) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils) | (3) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils) | (3) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils) | (3) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils) | ||||
| (4) - Its functioning relies on fluorinated greenhouse gases | (4) - Its functioning relies on fluorinated greenhouse gases | (4) - Its functioning relies on fluorinated greenhouse gases | (4) - Its functioning relies on fluorinated greenhouse gases | ||||