Specifications Table for RZQG-L9V1

RZQG71L9V1B_AMB RZQG71L9V1B RZQG100L9V1B RZQG125L9V1B RZQG140L9V1B
Sound pressure level Heating High dBA 12
    Nom. dBA 50 50 52 53 53
    Low dBA 12
  Cooling Low dBA 12
    High dBA 12
    Nom. dBA 48 48 50 51 52
  Night quiet mode Level 1 dBA 43 43 45 45 45
Refrigerant Charge TCO2Eq 6.1
  GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Charge kg 2.9 2.9 4.0 4.0 4.0
  Type   R-410A R-410A R-410A R-410A R-410A
Fan motor Output W 94
  Speed Cooling Super low rpm 12
    Heating Super low rpm 12
Operation range Cooling Ambient Max. °CDB 50 50.0 50.0 50.0 50.0
      Min. °CDB -15 -15.0 -15.0 -15.0 -15.0
  Heating Ambient Max. °CWB 15.5 15.5 15.5 15.5 15.5
      Min. °CWB -20 -20.0 -20.0 -20.0 -20.0
Piping connections Liquid OD mm   9.52 9.52 9.52 9.52
  Level difference IU - IU Max. m 0.5
    IU - OU Max. m 30.0
  Additional refrigerant charge kg/m See installation manual
  Total piping length System Actual m 12
Sound power level Cooling dBA 64 64.0 66.0 67.0 69.0
  Heating dBA 12 64.0 66.0 67.0 69.0
Capacity control step % 100-0
Dimensions Unit Width mm 940 940 940 940 940
    Depth mm 320 320 320 320 320
    Height mm 990 990 1,430 1,430 1,430
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Weight Unit kg 69
Fan Air flow rate Heating Super low cfm 12.000
      Super low m³/min 12.000
    Cooling Super low m³/min 12.000
      Super low cfm 12.000
Current - 50Hz Maximum fuse amps (MFA) A   25 40 40 40
Power supply Phase   1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240
Notes (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - 3 with re-charging (1) - 3 with re-charging (1) - 3 with re-charging (1) - 3 with re-charging
  (2) - 3 with re-charging (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
  (3) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Ssc: Short-circuit power (3) - Ssc: Short-circuit power (3) - Ssc: Short-circuit power (3) - Ssc: Short-circuit power
  (4) - See separate drawing for electrical data (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (5) - Contains fluorinated greenhouse gases (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data
  (6) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing. (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
Weight Unit kg   69.0 95.0 95.0 95.0
Piping connections Gas OD mm   15.9 15.9 15.9 15.9
  Piping length OU - IU Max. m   50 75 75 75
    System Equivalent m   70 90 90 90
      Chargeless m   30 30 30 30
  Additional refrigerant charge kg/m   See installation manual See installation manual See installation manual See installation manual
  Level difference IU - OU Max. m   30.0 30.0 30.0 30.0
    IU - IU Max. m   0.5 0.5 0.5 0.5
Standard Accessories Tie-wraps   2 2 2 2
  Installation manual   1 1 1 1