| RD20JEV1K | RD25JEV1K | RD30JEV1K | RD40JEV1K | RD40JEY1K | RD50JEY1K | RD60JEY1K | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Cooling | Nom. | dBA | 52 | 52 | 56 | 68 | 68 | 67 | 66 |
| Refrigerant | Charge | kg | 1.45 | 1.60 | 2.10 | 1.80 | 1.80 | 2.60 | 4.25 | |
| Type | R-22 | R-22 | R-22 | R-22 | R-22 | R-22 | R-22 | |||
| Dimensions | Unit | Width | mm | 855 | 855 | 855 | 1,030 | 1,030 | 1,030 | 1,030 |
| Depth | mm | 328 | 328 | 328 | 400 | 400 | 400 | 400 | ||
| Height | mm | 651 | 753 | 753 | 852 | 852 | 852 | 852 | ||
| Compressor | Type | Rotary | Rotary | Twin rotary | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | ||
| Weight | Unit | kg | 47 | 57 | 70 | 88 | 88 | 105 | 108 | |
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 3~ | 3~ | 3~ | ||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | 380-415 | 380-415 | 380-415 | ||
| Notes | (1) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (1) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (1) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | |||||||
| (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | |||||||
| (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | |||||||