Specifications Table for FXKQ-MA

FXKQ25MAVE9 FXKQ25MAVE FXKQ32MAVE9 FXKQ32MAVE FXKQ40MAVE9 FXKQ40MAVE FXKQ63MAVE9 FXKQ63MAVE
Sound pressure level Cooling At low fan speed dBA 33.0 33.0 33.0 33.0 34.0 34.0 37.0 37.0
    At high fan speed dBA 38.0 38.0 38.0 38.0 40.0 40.0 42.0 42.0
Standard Accessories Operation manual Operation manual Operation manual Operation manual Operation manual Operation manual Operation manual Operation manual Operation manual
  Installation manual Installation manual Installation manual Installation manual Installation manual Installation manual Installation manual Installation manual Installation manual
  Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation Paper pattern for installation
  Clamps Clamps Clamps Clamps Clamps Clamps Clamps Clamps Clamps
  Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket Insulation for hanger bracket
  Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation Positioning jig for installation
  Drain hose Drain hose Drain hose Drain hose Drain hose Drain hose Drain hose Drain hose Drain hose
  Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal
  Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting Insulation for fitting
  Sealing pads Sealing pads Sealing pads Sealing pads Sealing pads Sealing pads Sealing pads Sealing pads Sealing pads
  Screws Screws Screws Screws Screws Screws Screws Screws Screws
  Washer Washer Washer Washer Washer Washer Washer Washer Washer
  Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad Air outlet blocking pad
Refrigerant GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Power input - 50Hz Cooling At high fan speed kW 0.066 0.066 0.066 0.066 0.076 0.076 0.105 0.105
  Heating At high fan speed kW 0.046 0.046 0.046 0.046 0.056 0.056 0.085 0.085
Cooling capacity Total capacity At high fan speed kW 2.8 (1) 2.8 (1) 3.6 (1) 3.6 (1) 4.5 (1) 4.5 (1) 7.10 (1) 7.10 (1)
Piping connections Liquid OD mm 6.4 6.35 6.4 6.35 6.4 6.35 9.5 9.52
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Gas OD mm 12.7 12.7 12.7 12.7 12.7 12.7 15.9 15.9
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Drain   VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25)
Sound power level Cooling At high fan speed dBA 54 54 54 54 56 56 58 58
Air filter Type   Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance
Dimensions Unit Width mm 1,110 1,110 1,110 1,110 1,110 1,110 1,310 1,310
    Depth mm 710 710 710 710 710 710 710 710
    Height mm 215 215 215 215 215 215 215 215
Casing Material   Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Weight Unit kg 31 31 31 31 31 31 34 34
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 11 11 11 11 13 13 18 18
      At low fan speed m³/min 9 9 9 9 10 10 15 15
  Air flow rate - 60Hz Cooling High m³/min 11 11 11 11 13 13 18 18
      Low m³/min 8.5 8.5 8.5 8.5 10 10 13 13
Decoration panel Weight kg 8.5 8.5 8.5 8.5 8.5 8.5 9.5 9.5
  Model   BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK71FJW1 BYK71FJW1
  Dimensions Height mm 70 70 70 70 70 70 70 70
    Depth mm 800 800 800 800 800 800 800 800
    Width mm 1,240 1,240 1,240 1,240 1,240 1,240 1,440 1,440
  Colour   White White White White White White White White
Heating capacity Total capacity At high fan speed kW 3.2 (2) 3.2 (2) 4.0 (2) 4.0 (2) 5.0 (2) 5.0 (2) 8.00 (2) 8.00 (2)
Current - 50Hz Maximum fuse amps (MFA) A 15 15 15 15 15 15 15 15
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name   VE VE VE VE VE VE VE VE
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
  (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%.
  (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA
  (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA
  (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A
  (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA
  (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse. (10) - Use a circuit breaker instead of a fuse.
  (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases