| FWC06B5FV1B | FWC07B5FV1B | FWC08B5FV1B | FWC09B5FV1B | |||||
|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Low | dBA | 21.0 | 22.0 | 24.0 | 28.0 | ||
| High | dBA | 29.0 | 33.0 | 39.0 | 43.0 | |||
| Standard Accessories | Installation and operation manual | 1 | 1 | 1 | 1 | |||
| Installation guide | 1 | 1 | 1 | 1 | ||||
| Drain hose | 1 | 1 | 1 | 1 | ||||
| Metal clamp for drain hose | 1 | 1 | 1 | 1 | ||||
| Washer for hanger bracket | 8 | 8 | 8 | 8 | ||||
| Screws | 4 | 4 | 4 | 4 | ||||
| O ring | 4 | 4 | 4 | 4 | ||||
| Insulation | 6 | 6 | 6 | 6 | ||||
| Total sound power level | Low | dBA | 33.0 | 36.0 | 36.0 | 40.0 | ||
| High | dBA | 43.0 | 47.0 | 53.0 | 57.0 | |||
| Water flow | Water pressure drop | Heating | High | kPa | 18 | 22 | 30 | 38 |
| Cooling | High | kPa | 15 | 18 | 23 | 30 | ||
| Piping connections | Drain | OD | mm | VP25 (External dia.32, internal dia. 25) | VP25 (External dia.32, internal dia. 25) | VP25 (External dia.32, internal dia. 25) | VP25 (External dia.32, internal dia. 25) | |
| Water | Inlet | 3/4" BSP (female thread) | 3/4" BSP (female thread) | 3/4" BSP (female thread) | 3/4" BSP (female thread) | |||
| Outlet | 3/4" BSP (female thread) | 3/4" BSP (female thread) | 3/4" BSP (female thread) | 3/4" BSP (female thread) | ||||
| Power input | High | kW | 0.046 | 0.055 | 0.077 | 0.107 | ||
| Low | kW | 0.035 | 0.038 | 0.040 | 0.046 | |||
| Allowed water temperature | Heating | Max. | °C | 70 (4) | 70 (4) | 70 (4) | 70 (4) | |
| Min. | °C | 5 (4) | 5 (4) | 5 (4) | 5 (4) | |||
| Cooling | Min. | °C | 5 (4) | 5 (4) | 5 (4) | 5 (4) | ||
| Max. | °C | 70 (4) | 70 (4) | 70 (4) | 70 (4) | |||
| Dimensions | Unit | Width | mm | 840 | 840 | 840 | 840 | |
| Depth | mm | 840 | 840 | 840 | 840 | |||
| Height | mm | 288 | 288 | 288 | 288 | |||
| Weight | Unit | kg | 29 | 29 | 29 | 29 | ||
| Fan | Air flow rate | Low | m³/h | 708 | 804 | 852 | 1,014 | |
| High | m³/h | 1,032 | 1,200 | 1,476 | 1,746 | |||
| Cooling capacity (standard conditions) | Total capacity 4-pipe | Low | kW | 4.3 (1) | 4.6 (1) | 4.8 (1) | 5.7 (1) | |
| High | kW | 5.9 (1) | 6.3 (1) | 7.2 (1) | 8.3 (1) | |||
| Sensible capacity 4-pipe | Low | kW | 3.1 (1) | 3.3 (1) | 3.5 (1) | 4.0 (1) | ||
| High | kW | 4.2 (1) | 4.6 (1) | 5.4 (1) | 6.4 (1) | |||
| Heating capacity (standard conditions) | Capacity 4-pipe | Low | kW | 5.2 (3) | 5.5 (3) | 5.8 (3) | 6.8 (3) | |
| High | kW | 6.9 (3) | 7.8 (3) | 9.2 (3) | 10.4 (3) | |||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | |||
| Notes | (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C | (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C | (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C | (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C | ||||
| (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C | (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C | (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C | (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C | |||||
| (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C | (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C | (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C | (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C | |||||
| (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit | (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit | (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit | (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit | |||||