Specifications Table for FVXS-F / RXS-K

FVXS25FV1B / RXS25K2V1B FVXS25FV1B / RXS25K3V1B FVXS35FV1B / RXS35K2V1B FVXS50FV1B / RXS50K2V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.4
  Max. kW 3.0 3.0 3.8 5.6
  Nom. kW 2.5 (3) 2.5 (2) 3.5 (2) 5.0 (2)
Space cooling SEER     4.71 4.93 5.53
  Annual energy consumption kWh/a   186 248 317
  Capacity Pdesign kW   2.50 3.50 5.00
  Energy efficiency class     B B A
Space heating (Average climate) Capacity Pdesign kW   2.60 2.90 4.80
  SCOP/A     4.38 3.83 3.62
  Energy efficiency class     A+ A A
  Annual energy consumption kWh/a   830 1,060 1,853
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 12.7
  Drain OD mm 20 20.0 20.0 20.0
Nominal efficiency EER   4.39 4.39 3.43 3.23
  Annual energy consumption kWh 285 285 510 775
  COP   4.30 4.30 3.69 3.63
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 3.4 (4) 3.4 (3) 4.5 (3) 5.8 (3)
  Min. kW 1.3 1.3 1.4 1.4
  Max. kW 4.5 4.5 5.0 8.1
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (4) - 220V (4) - 220V (4) - 220V
  (5) - 220V (5) - 230V (5) - 230V (5) - 230V
  (6) - 230V (6) - 240V (6) - 240V (6) - 240V
  (7) - 240V (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load