| FTY18HEVLK / RY18HEVLK | FTY24HEVLK / RY24HEVLK | FTY30HEVLK / RY30HEVLK | ||||
|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.45 (3), 4.70 (5) | 6.25 (3), 5.37 (5) | 8.01 (3), 7.10 (5) | |
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 9.52 |
| Gas | OD | mm | 12.7 | 15.9 | 15.9 | |
| Nominal efficiency | EER | 2.42, 8.25 (8), 1.79, 6.12 (8) | 2.53 (1), 8.64 (8), 1.94, 6.62 (8) | 2.43, 8.29 (8), 1.86, 6.35 (8) | ||
| Annual energy consumption | kWh | 2,725 | 3,125 | 4,005 | ||
| COP | 3.03, 10.34 (8) | 2.82, 9.62 (8) | 2.78, 9.49 (8) | |||
| Heating capacity | Nom. | kW | 6.45 | 6.83 | 8.96 | |
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (3) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (3) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | ||||
| (4) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (4) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (4) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | ||||
| (5) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (5) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (5) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | ||||
| (6) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (6) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (6) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | ||||
| (7) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (7) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (7) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | ||||
| (8) - Btu/W | (8) - Btu/W | (8) - Btu/W | ||||
| (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||