| FTXM20N2V1B / RXM20R5V1B | FTXM25N2V1B / RXM25R5V1B | FTXM35N2V1B / RXM35R5V1B | ||||
|---|---|---|---|---|---|---|
| Outdoor unit | RXM20R5V1B | RXM25R5V1B | RXM35R5V1B | |||
| Cooling capacity | Min. | kW | 1.30 | 1.30 | 1.40 | |
| Nom. | kW | 2.00 | 2.50 | 3.40 | ||
| Max. | kW | 2.60 | 3.20 | 4.00 | ||
| Heating capacity | Min. | kW | 1.30 | 1.30 | 1.40 | |
| Nom. | kW | 2.50 | 2.80 | 4.00 | ||
| Max. | kW | 3.50 | 4.70 | 5.20 | ||
| Nominal efficiency | Annual energy consumption | kWh | 219 | 278 | 402 | |
| COP | 5.00 | 5.00 | 4.04 | |||
| EER | 4.57 | 4.50 | 4.23 | |||
| Energy labeling Directive | Cooling | A | A | A | ||
| Heating | A | A | A | |||
| Space cooling | Annual energy consumption | kWh/a | 81 | 101 | 138 | |
| Energy efficiency class | A+++ | A+++ | A+++ | |||
| Capacity | Pdesign | kW | 2.00 | 2.50 | 3.40 | |
| SEER | 8.65 | 8.65 | 8.65 | |||
| Space heating (Average climate) | Annual energy consumption | kWh/a | 632 | 659 | 687 | |
| Capacity | Pdesign | kW | 2.30 | 2.40 | 2.50 | |
| Energy efficiency class | A+++ | A+++ | A+++ | |||
| Pdh Heating capacity at -10° | kW | 2.24 | 2.30 | 2.35 | ||
| SCOP/A | 5.10 | 5.10 | 5.10 | |||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | |||
| (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||