Specifications Table for FTXM-N / 4MXM-A8

FTXM20N2V1B / FTXM50N2V1B / 4MXM68A2V1B8 FTXM20N2V1B / FTXM20N2V1B / FTXM25N2V1B / 4MXM68A2V1B8 FTXM20N2V1B / FTXM25N2V1B / FTXM25N2V1B / 4MXM68A2V1B8 FTXM25N2V1B / FTXM42N2V1B / 4MXM68A2V1B8 FTXM35N2V1B / FTXM35N2V1B / 4MXM68A2V1B8 FTXM20N2V1B / FTXM25N2V1B / FTXM35N2V1B / 4MXM80A2V1B8 FTXM20N2V1B / FTXM60N2V1B / 4MXM80A2V1B8 FTXM20N2V1B / FTXM20N2V1B / FTXM20N2V1B / FTXM20N2V1B / 4MXM80A2V1B8 FTXM20N2V1B / FTXM20N2V1B / FTXM42N2V1B / 4MXM80A2V1B8 FTXM35N2V1B / FTXM42N2V1B / 4MXM80A2V1B8
Cooling capacity Nom. kW 6.8 6.5 6.8 6.7 6.8 7.40 7.40 7.40 8.00 7.70
Heating capacity Nom. kW 8.60 8.20 8.60 8.30 8.60 9.30 9.30 9.60 9.40 9.00
Nominal efficiency EER   3.59 4.01 3.85 3.74 3.94 3.79 3.43 4.17 3.56 3.11
  COP   3.82 4.49 4.38 3.95 3.81 4.02 3.73 4.58 4.08 3.56
  Annual energy consumption kWh 947 810 883 896 863 977 1079 887 1125 1236
  Energy labeling Directive Cooling   A A A A A A A A A B
    Heating   A A A A A A A A A B
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 6.80 6.50 6.80 6.70 6.80 7.40 7.40 7.40 8.00 7.70
  SEER   6.75 7.76 7.71 6.94 6.97 7.07 6.73 7.40 6.93 6.52
  Annual energy consumption kWh/a 352 294 309 338 342 370 387 351 405 417
Space heating (Average climate) Energy efficiency class   A A+ A+ A A+ A+ A+ A+ A+ A+
  Capacity Pdesign kW 4.50 5.30 5.30 4.30 4.80 5.37 4.27 6.23 5.37 4.27
  SCOP/A   3.90 4.09 4.10 3.86 4.00 4.31 4.33 4.56 4.34 4.23
  Pdh Heating capacity at -10° kW 3.55 4.21 4.22 3.41 3.73 4.37 3.71 4.73 4.34 3.68
  Annual energy consumption kWh/a 1612 1814 1807 1559 1679 1744 1382 1913 1732 1413
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data