| FTXM20N2V1B / FTXM20N2V1B / 3MXM40A2V1B8 | FTXM25N2V1B / FTXM25N2V1B / 3MXM52A2V1B8 | FTXM20N2V1B / FTXM50N2V1B / 3MXM68A2V1B8 | FTXM20N2V1B / FTXM20N2V1B / FTXM25N2V1B / 3MXM68A2V1B8 | FTXM20N2V1B / FTXM25N2V1B / FTXM25N2V1B / 3MXM68A2V1B8 | FTXM25N2V1B / FTXM42N2V1B / 3MXM68A2V1B8 | FTXM35N2V1B / FTXM35N2V1B / 3MXM68A2V1B8 | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | 5.00 | 6.8 | 6.5 | 6.8 | 6.7 | 6.8 | |
| Heating capacity | Nom. | kW | 4.60 | 6.80 | 8.60 | 8.20 | 8.60 | 8.30 | 8.60 | |
| Nominal efficiency | EER | 4.76 | 4.85 | 3.59 | 4.01 | 3.85 | 3.74 | 3.94 | ||
| COP | 4.73 | 4.45 | 3.82 | 4.49 | 4.38 | 3.95 | 3.81 | |||
| Annual energy consumption | kWh | 420 | 515 | 947 | 810 | 883 | 896 | 863 | ||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | |||
| Space cooling | Energy efficiency class | A+++ | A+++ | A++ | A++ | A++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 4.00 | 5.00 | 6.80 | 6.50 | 6.80 | 6.70 | 6.80 | |
| SEER | 8.53 | 8.59 | 6.75 | 7.76 | 7.71 | 6.94 | 6.97 | |||
| Annual energy consumption | kWh/a | 164 | 204 | 352 | 294 | 309 | 338 | 342 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | A | A+ | A+ | A | A+ | ||
| Capacity | Pdesign | kW | 4.80 | 4.80 | 4.50 | 5.30 | 5.30 | 4.30 | 4.80 | |
| SCOP/A | 4.25 | 4.38 | 3.90 | 4.09 | 4.10 | 3.86 | 4.00 | |||
| Pdh Heating capacity at -10° | kW | 3.60 | 3.90 | 3.55 | 4.21 | 4.21 | 3.41 | 3.73 | ||
| Annual energy consumption | kWh/a | 1582 | 1533 | 1612 | 1814 | 1807 | 1559 | 1680 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||