| FHYC20JEVLK / RYD20JEVLK | FHYC25JEVLK / RYD25JEVLK | FHYC30JEVLK / RYD30JEVLK | FHYC40JEVLK / RYD40JEVLK | FHYC50JEVLK / RYD50JETLK | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.720 | 6.830 | 8.210 | 10.550 | 13.920 | |
| Nominal efficiency | EER | 2.77 | 2.64 | 2.64 | 2.63 | 2.58 | ||
| Annual energy consumption | kWh | 1,030 | 1,295 | 1,555 | 2,005 | 2,690 | ||
| COP | 3.26 | 3.12 | 3.40 | 3.08 | 2.92 | |||
| Energy labeling Directive | Cooling | D | D | D | D | E | ||
| Heating | C | D | C | D | D | |||
| Heating capacity | Nom. | kW | 5.860 (4) | 7.180 (4) | 8.790 (4) | 11.250 (4) | 14.650 (4) | |
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | ||||
| (5) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (5) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (5) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (5) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (5) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | ||||
| (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||