Specifications Table for FFA-A9 / RXM-N

FFA50A2VEB9 / RXM50N2V1B FFA60A2VEB9 / RXM60N2V1B
Cooling capacity Nom. kW 5.00
Space cooling SEER   5.98
  Annual energy consumption kWh/a 292
  Capacity Pdesign kW 5.00
  Energy efficiency class   A+
Space heating (Average climate) Capacity Pdesign kW 3.84
  SCOP/A   3.90
  Energy efficiency class   A
  Annual energy consumption kWh/a 1,377
Nominal efficiency Annual energy consumption kWh 772
  EER   3.24
  COP   3.49
  Energy labeling Directive Cooling   A
    Heating   A
Heating capacity Nom. kW 5.80
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data
Outdoor unit   RXM60N2V1B
Cooling capacity Nom. kW   5.70
Heating capacity Nom. kW   7.00
Nominal efficiency EER     3.05
  COP     3.41
  Annual energy consumption kWh   934
  Energy labeling Directive Cooling     B
    Heating     B
Space cooling Energy efficiency class     A+
  Capacity Pdesign kW   5.70
  SEER     5.76
  Annual energy consumption kWh/a   347
Space heating (Average climate) Energy efficiency class     A+
  Capacity Pdesign kW   3.96
  SCOP/A     4.04
  Pdh Heating capacity at -10° kW   3.66
  Annual energy consumption kWh/a   1372
Energy Efficiency Range   A+++ ~ D