Specifications Table for FDYM-JVL/JYL / RYD-JVL/JTL/JYL

FDYM20JEVLK / RYD20JEVLK FDYM25JEVLK / RYD25JEVLK FDYM30JEVLK / RYD30JEVLK FDYM40JEVLK / RYD40JEVLK FDYM50JEVLK / RYD50JETLK FDYM60JEVLK / RYD60JETLK
Cooling capacity Nom. kW 5.570 (3) 6.830 (3) 8.353 (3) 10.551 (3) 14.068 (3) 16.120 (3)
Piping connections Liquid OD mm 6.35 9.52 9.52 9.52 9.52 12.7
  Gas OD mm 15.88 15.88 15.88 19.05 19.05 19.05
Nominal efficiency EER   2.77 2.62 2.61 2.71 2.62 2.60
  Annual energy consumption kWh 1,005 1,305 1,625 1,985 2,778 3,218
  COP   3.27 3.26 3.33 3.09 3.23 3.19
  Energy labeling Directive Cooling   D D D D D E
    Heating   C C C D C D
Heating capacity Nom. kW 6.150 (4) 7.180 (4) 8.790 (4) 11.723 (4) 14.654 (4) 17.585 (4)
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB
  (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB
  (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB
  (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit).
  (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load