| FDYM20JEVLK / RYD20JEVLK | FDYM25JEVLK / RYD25JEVLK | FDYM30JEVLK / RYD30JEVLK | FDYM40JEVLK / RYD40JEVLK | FDYM50JEVLK / RYD50JETLK | FDYM60JEVLK / RYD60JETLK | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.570 (3) | 6.830 (3) | 8.353 (3) | 10.551 (3) | 14.068 (3) | 16.120 (3) | |
| Piping connections | Liquid | OD | mm | 6.35 | 9.52 | 9.52 | 9.52 | 9.52 | 12.7 |
| Gas | OD | mm | 15.88 | 15.88 | 15.88 | 19.05 | 19.05 | 19.05 | |
| Nominal efficiency | EER | 2.77 | 2.62 | 2.61 | 2.71 | 2.62 | 2.60 | ||
| Annual energy consumption | kWh | 1,005 | 1,305 | 1,625 | 1,985 | 2,778 | 3,218 | ||
| COP | 3.27 | 3.26 | 3.33 | 3.09 | 3.23 | 3.19 | |||
| Energy labeling Directive | Cooling | D | D | D | D | D | E | ||
| Heating | C | C | C | D | C | D | |||
| Heating capacity | Nom. | kW | 6.150 (4) | 7.180 (4) | 8.790 (4) | 11.723 (4) | 14.654 (4) | 17.585 (4) | |
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 8°CDB, 6°CWB | ||||
| (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (6) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | ||||
| (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||