Specifications Table for FDYM-C

FDYM30CV1M FDYM40CV1M FDYM60CV1M FDYM71CV1M FDYM80CV1M FDYM90CV1M FDYM100CV1M FDYM125CV1M FDYM140CV1M FDYM160CV1M
Sound pressure level Cooling Super high dBA         44 49 55 51 53 55
    Low dBA 20 29 34 36 34 38 45 41 47 47
    High dBA 33 37 38 40 41 46 51 49 52 53
    Nom. dBA 26 34 36 39 38 42 48 45 50 50
Standard Accessories SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset
Sound power level Cooling dBA 57 61 65 66 64 73 76 76 76 78
Dimensions Unit Width mm 765 905 1,065 1,200 1,007 929 1,302 1,045 1,299 1,499
    Depth mm 411 411 411 411 600 541 638 541 541 541
    Height mm 261 261 261 261 285 378 305 378 378 378
Casing Material   Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel
  Colour   Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint
Weight Unit kg 17 21 22 25 38 39 41 42 54 62
Fan External static pressure High Pa 49 49 69 41 78 167 118 176 157 157
    Nom. Pa 39 39 65 31 68 127 108 127 137 137
    Low Pa 29 20 42 18 59 88 88 93 108 98
    Super high Pa         98 206 137 206 176 176
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name   V1 V1 V1 V1 V1 V1 V1 V1 V1 V1
  Frequency Hz 50 50 50 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room.
  (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit).
  (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E).