| FDYM30CV1M | FDYM40CV1M | FDYM60CV1M | FDYM71CV1M | FDYM80CV1M | FDYM90CV1M | FDYM100CV1M | FDYM125CV1M | FDYM140CV1M | FDYM160CV1M | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Cooling | Super high | dBA | 44 | 49 | 55 | 51 | 53 | 55 | ||||
| Low | dBA | 20 | 29 | 34 | 36 | 34 | 38 | 45 | 41 | 47 | 47 | ||
| High | dBA | 33 | 37 | 38 | 40 | 41 | 46 | 51 | 49 | 52 | 53 | ||
| Nom. | dBA | 26 | 34 | 36 | 39 | 38 | 42 | 48 | 45 | 50 | 50 | ||
| Standard Accessories | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | SLM wired handset | ||
| Sound power level | Cooling | dBA | 57 | 61 | 65 | 66 | 64 | 73 | 76 | 76 | 76 | 78 | |
| Dimensions | Unit | Width | mm | 765 | 905 | 1,065 | 1,200 | 1,007 | 929 | 1,302 | 1,045 | 1,299 | 1,499 |
| Depth | mm | 411 | 411 | 411 | 411 | 600 | 541 | 638 | 541 | 541 | 541 | ||
| Height | mm | 261 | 261 | 261 | 261 | 285 | 378 | 305 | 378 | 378 | 378 | ||
| Casing | Material | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | Galvanised steel | ||
| Colour | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | |||
| Weight | Unit | kg | 17 | 21 | 22 | 25 | 38 | 39 | 41 | 42 | 54 | 62 | |
| Fan | External static pressure | High | Pa | 49 | 49 | 69 | 41 | 78 | 167 | 118 | 176 | 157 | 157 |
| Nom. | Pa | 39 | 39 | 65 | 31 | 68 | 127 | 108 | 127 | 137 | 137 | ||
| Low | Pa | 29 | 20 | 42 | 18 | 59 | 88 | 88 | 93 | 108 | 98 | ||
| Super high | Pa | 98 | 206 | 137 | 206 | 176 | 176 | ||||||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | ||
| Name | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | ||
| Notes | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. | |||
| (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). | ||||
| (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | (3) - All units are being tested and comply to ISO5151:1994(E). | ||||