Specifications Table for FDYB-C

FDYB30CV1M FDYB40CV1M FDYB60CV1M FDYB71CV1M FDYB90CV1M FDYB125CV1M FDYB140CV1M FDYB160CV1M
Sound pressure level Cooling Super high dBA         49 51 53 55
    Low dBA 26 29 34 36 38 41 47 47
    High dBA 33 37 38 40 46 49 52 53
    Nom. dBA 30 34 36 39 42 45 50 50
Standard Accessories SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset SLM wired handset
Sound power level Cooling dBA 57 61 65 66 73 76 76 78
Dimensions Unit Width mm 765 765 1,065 1,200 929 1,045 1,299 1,499
    Depth mm 411 411 411 411 541 541 541 541
    Height mm 261 261 261 261 378 378 378 378
Casing Material   Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel
  Colour   Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint Without powder paint
Weight Unit kg 17 21 22 25 39 42 54 62
Fan External static pressure High Pa 20 20 29 25 39 39 59 49
    Nom. Pa 9.8 9.8 20 15 29 29 39 29
    Low Pa 4.9 4.9 9.8 5 20 20 20 20
    Super high Pa         49 49 78 69
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name   V1 V1 V1 V1 V1 V1 V1 V1
  Frequency Hz 50 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room. (1) - Sound power: test with 5ft length discharge duct, terminated flush with internal wall of reverberation room.
  (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit). (2) - Sound pressure: tested with 2m length duct at the air discharge outlet and air return inlet (1.4m below the centre of the unit).
  (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E). (3) - All units are being tested and comply to ISO5151:1994(E).