| FDM36PEV1K / R36PEY1K | FDM42PEV1K / R42PEY1K | FDM48PEV1K / R48PEY1K | FDM24PEV1K / R24PEV1K | FDM30PEV1K / R30PEV1K | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 9.7 | 11.3 | 13.0 | 6.8 | 7.7 | |
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | |||
| Gas | OD | mm | 15.9 | 15.9 | ||||
| Nominal efficiency | EER | 2.49 (1), 8.46 (2) | 2.46 (1), 8.39 (2) | 2.40 (1), 8.22 (2) | 2.72 (1), 9.28 (2) | 2.64 (1), 9.01 (2) | ||
| Annual energy consumption | kWh | 1,950 | 2,300 | 2,700 | 1,250 | 1,460 | ||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (1) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (1) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (1) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | (1) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1 | |||
| (2) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (2) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (2) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (2) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | (2) - Cooling: indoor temp. 27°CDB, 19.5°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); Standard: T1, Btu/h | ||||
| (3) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (3) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (3) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (3) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | (3) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3 | ||||
| (4) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (4) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (4) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (4) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | (4) - Cooling: indoor temp. 29°CDB, 19°CWB; outdoor temp. 46°CDB, 24°CWB; equivalent piping length: 7.5m (horizontal); SASO Standard - T3, Btu/h | ||||
| (5) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (5) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (5) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (5) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (5) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| Piping connections | Liquid | OD | mm | 12.7 | 12.7 | 12.7 | ||
| Gas | OD | mm | 19.1 | 19.1 | 19.1 | |||