| FDM20JEV1K | FDM25JEV1K | FDM30JEV1K | FDM40JEV1K | FDM50JEV1K | FDM60JEV1K | ||||
|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Cooling | Low | dBA | 38 | 38 | 39 | 44 | 52 | 54 |
| High | dBA | 40 | 41 | 45 | 46 | 55 | 58 | ||
| Nom. | dBA | 39 | 40 | 44 | 45 | 53 | 56 | ||
| Piping connections | Drain | 19.1 | 19.1 | 19.1 | 19.1 | 19.1 | 19.1 | ||
| Dimensions | Unit | Width | mm | 1,065 | 1,200 | 1,228 | 1,228 | 1,299 | 1,499 |
| Depth | mm | 411 | 411 | 420 | 420 | 541 | 541 | ||
| Height | mm | 261 | 261 | 292 | 292 | 378 | 378 | ||
| Casing | Colour | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | Without powder paint | ||
| Weight | Unit | kg | 24 | 26 | 32 | 32 | 54 | 62 | |
| Fan | External static pressure | High | Pa | 40 | 50 | 50 | 50 | 50 | 50 |
| Nom. | Pa | 38 | 46 | 50 | 50 | 50 | 50 | ||
| Low | Pa | 35 | 36 | 50 | 50 | 50 | 50 | ||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | ||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | ||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | ||
| Notes | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | (1) - All units are being tested and comply to ISO 5151 (Non-ducted unit) | |||
| (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | (2) - All specifications are subjected to change by the manufacturer without prior notice. | ||||
| (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | (3) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 35 DEG C OD DB (HIGH FAN) | ||||
| (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | (4) - GROSS CAPACITY BASED @ 27/19 DEG C ID DB/WB & 46 DEG C OD DB (HIGH FAN) | ||||
| (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | (5) - EER IS CALCULATED BASED ON GROSS CAPACITY | ||||