EHVZ04S18CB3V / ERLQ004CAV3 |
EHVZ08S18CB3V / ERLQ006CAV3 |
EHVZ08S18CB3V / ERLQ008CAV3 |
EHVZ16S18CB3V / ERLQ011CAV3 |
EHVZ16S18CB3V / ERLQ014CAV3 |
EHVZ16S18CB3V / ERLQ016CAV3 |
Domestic hot water heating
|
General
|
Declared load profile
|
|
L
|
L
|
L
|
L
|
L
|
L
|
|
Average climate
|
Water heating energy efficiency class
|
|
A
|
A
|
A
|
A
|
A
|
A
|
COP
|
5.04 (1), 3.58 (2)
|
4.74 (1), 3.56 (2)
|
4.45 (1), 3.42 (2)
|
4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4)
|
4.24 (1), 2.61 (3), 3.28 (2), 2.05 (4)
|
4.22 (1), 2.61 (3), 3.23 (2), 2.07 (4)
|
Heating capacity
|
Nom.
|
kW
|
4.40 (1), 4.03 (2)
|
6.00 (1), 5.67 (2)
|
7.40 (1), 6.89 (2)
|
11.2 (1), 11.0 (2)
|
14.4 (1), 13.5 (2)
|
15.9 (1), 15.1 (2)
|
|
Min.
|
kW
|
1.80 (1)
|
1.80 (1)
|
1.80 (1)
|
|
Max.
|
kW
|
5.12 (1), 4.90 (2)
|
8.35 (1), 7.95 (2)
|
10.0 (1), 9.53 (2)
|
8.60 (3), 8.60 (4)
|
10.5 (3), 10.7 (4)
|
11.3 (3), 10.8 (4)
|
Power input
|
Heating
|
Maks.
|
kW
|
|
|
|
3.13 (3), 4.10 (4)
|
4.02 (3), 5.21 (4)
|
4.33 (3), 5.22 (4)
|
|
|
Nom.
|
kW
|
0.870 (1), 1.13 (2)
|
1.27 (1), 1.59 (2)
|
1.66 (1), 2.01 (2)
|
2.43 (1), 3.10 (2)
|
3.39 (1), 4.12 (2)
|
3.77 (1), 4.67 (2)
|
Notes
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
(3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
|
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
(4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
|
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
(5) - Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).
|
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
(7) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
|
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|