| EHBH04CB3V | EHBH08CB9W | EHBH08CB3V | EHBH11CB3V | EHBH11CB9W | EHBH16CB3V | EHBH16CB9W | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Casing | Colour | White | White | White | White | White | White | White | |||
| Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | ||||
| Dimensions | Unit | Height | mm | 890 | 890 | 890 | 890 | 890 | 890 | 890 | |
| Width | mm | 480 | 480 | 480 | 480 | 480 | 480 | 480 | |||
| Depth | mm | 344 | 344 | 344 | 344 | 344 | 344 | 344 | |||
| Weight | Unit | kg | 41.0 | 45.0 | 43.0 | 43.0 | 44.0 | 44.0 | 45.0 | ||
| PED | Category | Art3§3, See note 1 | Category I, See note 1 | Category I, See note 1 | Art3§3, See note 1 | Art3§3, See note 1 | Art3§3, See note 1 | Art3§3, See note 1 | |||
| Sound power level | Nom. | dBA | 40.0 | 40.0 | 40.0 (4) | 41.0 (4) | 41.0 (4) | 44.0 (4) | 44.0 (4) | ||
| Sound pressure level | Nom. | dBA | 26.0 | 26.0 | 26.0 (5) | 27.0 (5) | 27.0 (5) | 30.0 (5) | 30.0 (5) | ||
| Operation range | Heating | Water side | Min. | °C | 15 | 15 | 15 (6) | 15 (6) | 15 (6) | 15 (6) | 15 (6) |
| Max. | °C | 55.0 | 55.0 | 55.0 | 55.0 (8) | 55.0 (8) | 55.0 (8) | 55.0 (8) | |||
| Power supply | Name | See note 11 | See note 11 | See note 11 | See note 11 | See note 11 | See note 11 | See note 11 | |||
| Electric heater | Power supply | Name | 3V3 | 9W | 3V3 | 3V3 | 9W | 3V3 | 9W | ||
| Phase | 1~ | Refer to installation manual or drawing 4D093592 | 1~ | 1~ | Refer to installation manual or drawing 4D093592 | 1~ | Refer to installation manual or drawing 4D093592 | ||||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | 230 | ||||||
| Wiring connections | For connection with user interface | Quantity | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| Remark | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | ||||
| Notes | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | ||||
| (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | (2) - Including piping + PHE + back-up heater; excluding expansion vessel | |||||
| (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | |||||
| (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. | |||||
| (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning | |||||
| (6) - > 50°C BSH only, no heatpump | (6) - > 50°C BSH only, no heatpump | (6) - > 50°C BSH only, no heatpump | (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | |||||
| (7) - > 50°C BSH only, no heatpump | (7) - > 50°C BSH only, no heatpump | (7) - > 50°C BSH only, no heatpump | (7) - > 50°C BSH only, no heatpump | ||||||||