2MXM40M2V1B |
2MXM40M3V1B |
2MXM40M4V1B |
2MXM50M2V1B |
Sound pressure level
|
Heating
|
High
|
dBA
|
|
48
|
48
|
|
|
Nom.
|
dBA
|
50
|
|
|
48
|
|
Cooling
|
High
|
dBA
|
|
46
|
46
|
|
|
Nom.
|
dBA
|
48
|
|
|
46
|
Standard Accessories
|
Installation manual
|
Installation manual
|
1
|
1
|
1
|
|
Screw bag
|
Screw bag
|
1
|
1
|
1
|
|
Drain plug
|
Drain plug
|
1
|
1
|
1
|
Refrigerant
|
Charge
|
TCO2Eq
|
0.6
|
0.59
|
0.60
|
0.8
|
|
GWP
|
|
675
|
675
|
675
|
675
|
|
Charge
|
kg
|
0.88
|
0.88
|
0.88
|
1.15
|
|
Type
|
|
R-32
|
R-32
|
R-32
|
R-32
|
Fan motor
|
Speed
|
Cooling
|
Super low
|
rpm
|
760
|
500
|
500
|
890
|
|
|
Heating
|
Super low
|
rpm
|
820
|
320
|
320
|
890
|
Operation range
|
Cooling
|
Ambient
|
Max.
|
°CDB
|
46
|
46 (2)
|
46
|
46
|
|
|
|
Min.
|
°CDB
|
-10
|
-10 (2)
|
-10
|
-10
|
|
Heating
|
Ambient
|
Max.
|
°CWB
|
18
|
18
|
18
|
18
|
|
|
|
Min.
|
°CWB
|
-15
|
-15
|
-15
|
-15
|
Piping connections
|
Level difference
|
IU - IU
|
Max.
|
m
|
7.5
|
7.5
|
7.5
|
7.5
|
|
|
IU - OU
|
Max.
|
m
|
15
|
15.0
|
15.0
|
15
|
|
Additional refrigerant charge
|
kg/m
|
0.02 (for piping length exceeding 20m)
|
0.02 (for piping length exceeding 20m)
|
0.02 (for piping length exceeding 20m)
|
0.02 (for piping length exceeding 20m)
|
|
Total piping length
|
System
|
Actual
|
m
|
30
|
30.0
|
30.0
|
30
|
Dimensions
|
Unit
|
Width
|
mm
|
765
|
765
|
765
|
765
|
|
|
Depth
|
mm
|
285
|
285
|
285
|
285
|
|
|
Height
|
mm
|
550
|
550
|
550
|
550
|
Compressor
|
Type
|
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Weight
|
Unit
|
kg
|
36
|
36
|
36
|
41
|
Fan
|
Air flow rate
|
Heating
|
Super low
|
cfm
|
1,130
|
|
|
1,200
|
|
|
|
Super low
|
m³/min
|
32
|
|
|
34
|
|
|
Cooling
|
Super low
|
m³/min
|
30
|
|
|
34
|
|
|
|
Super low
|
cfm
|
1,059
|
|
|
1,200
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
220-240
|
220-230-240
|
220-230-240
|
220-240
|
Notes
|
(1) - Contains fluorinated greenhouse gases
|
|
|
(1) - Contains fluorinated greenhouse gases
|
|
|
(1) - For one room
|
(1) - For one room
|
|
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for operation range
|
|
|
(3) - See separate drawing for electrical data
|
(3) - See separate drawing for electrical data
|
|
|
(4) - Contains fluorinated greenhouse gases
|
(4) - Contains fluorinated greenhouse gases
|
Standard Accessories
|
Reducer assembly
|
|
|
|
1
|