FXDQ15A3VEB |
FXDQ20A3VEB |
FXDQ25A3VEB |
FXDQ32A3VEB |
FXDQ40A3VEB |
FXDQ50A3VEB |
FXDQ63A3VEB |
Sound pressure level
|
Cooling
|
At low fan speed
|
dBA
|
27.0
|
27.0
|
27.0
|
27.0
|
28.0
|
29.0
|
30.0
|
|
|
At high fan speed
|
dBA
|
32.0
|
33.0
|
33.0
|
33.0
|
34.0
|
35.0
|
36.0
|
|
|
At medium fan speed
|
dBA
|
31.0
|
31.0
|
31.0
|
31.0
|
32.0
|
33.0
|
34.0
|
Refrigerant
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
Power input - 50Hz
|
Cooling
|
At high fan speed
|
kW
|
0.036 (1)
|
0.036 (1)
|
0.036 (1)
|
0.041 (1)
|
0.042 (1)
|
0.053 (1)
|
0.062 (1)
|
|
Heating
|
At high fan speed
|
kW
|
0.036 (1)
|
0.036 (1)
|
0.036 (1)
|
0.041 (1)
|
0.042 (1)
|
0.053 (1)
|
0.062 (1)
|
Cooling capacity
|
Nom.
|
kW
|
1.7
|
2.2
|
2.8
|
3.6
|
4.5
|
5.6
|
7.1
|
Piping connections
|
Liquid
|
OD
|
mm
|
6
|
6
|
6
|
6
|
6
|
6
|
10
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
12.7
|
12.7
|
12.7
|
12.7
|
12.7
|
12.7
|
15.9
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Drain
|
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
Required ceiling void >
|
mm
|
240
|
240
|
240
|
240
|
240
|
240
|
240
|
Sound power level
|
Cooling
|
At high fan speed
|
dBA
|
50
|
51
|
51
|
51
|
52
|
53
|
54
|
Air filter
|
Type
|
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Dimensions
|
Unit
|
Width
|
mm
|
750
|
750
|
750
|
750
|
950
|
950
|
1,150
|
|
|
Depth
|
mm
|
620
|
620
|
620
|
620
|
620
|
620
|
620
|
|
|
Height
|
mm
|
200
|
200
|
200
|
200
|
200
|
200
|
200
|
Casing
|
Material
|
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
|
Colour
|
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Weight
|
Unit
|
kg
|
22
|
22
|
22
|
22
|
26
|
26
|
29
|
Fan
|
External static pressure - 50Hz
|
High
|
Pa
|
30.0
|
30.0
|
30.0
|
30.0
|
44.0
|
44.0
|
44.0
|
|
Air flow rate - 50Hz
|
Cooling
|
At high fan speed
|
m³/min
|
7.5
|
8.0
|
8.0
|
8.0
|
10.5
|
12.5
|
16.5
|
|
|
|
At low fan speed
|
m³/min
|
6.4
|
6.4
|
6.4
|
6.4
|
8.5
|
10.0
|
13.0
|
Drain-up height
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
Heating capacity
|
Nom.
|
kW
|
1.9
|
2.5
|
3.2
|
4.0
|
5.0
|
6.3
|
8.0
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Name
|
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
|
Frequency
|
Hz
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
|
Voltage
|
V
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
Notes
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
(1) - Values are valid for the factory setting.
|
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
(8) - MCA/MFA: MCA = 1.25 x FLA
|
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
(9) - MFA ≤ 4 x FLA
|
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
(10) - Contains fluorinated greenhouse gases
|
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
(11) - Instead of a fuse, use a circuit breaker
|
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
(12) - Select wire size based on the value of MCA
|
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|
(13) - Next lower standard fuse rating minimum 15A
|