Specifications Table for FXDQ-A3

FXDQ15A3VEB FXDQ20A3VEB FXDQ25A3VEB FXDQ32A3VEB FXDQ40A3VEB FXDQ50A3VEB FXDQ63A3VEB
Sound pressure level Cooling At low fan speed dBA 27.0 27.0 27.0 27.0 28.0 29.0 30.0
    At high fan speed dBA 32.0 33.0 33.0 33.0 34.0 35.0 36.0
    At medium fan speed dBA 31.0 31.0 31.0 31.0 32.0 33.0 34.0
Refrigerant GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Power input - 50Hz Cooling At high fan speed kW 0.036 (1) 0.036 (1) 0.036 (1) 0.041 (1) 0.042 (1) 0.053 (1) 0.062 (1)
  Heating At high fan speed kW 0.036 (1) 0.036 (1) 0.036 (1) 0.041 (1) 0.042 (1) 0.053 (1) 0.062 (1)
Cooling capacity Nom. kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1
Piping connections Liquid OD mm 6 6 6 6 6 6 10
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Gas OD mm 12.7 12.7 12.7 12.7 12.7 12.7 15.9
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Drain   VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26)
Required ceiling void > mm 240 240 240 240 240 240 240
Sound power level Cooling At high fan speed dBA 50 51 51 51 52 53 54
Air filter Type   Removable / washable Removable / washable Removable / washable Removable / washable Removable / washable Removable / washable Removable / washable
Dimensions Unit Width mm 750 750 750 750 950 950 1,150
    Depth mm 620 620 620 620 620 620 620
    Height mm 200 200 200 200 200 200 200
Casing Material   Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel Galvanised steel
  Colour   Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised)
Weight Unit kg 22 22 22 22 26 26 29
Fan External static pressure - 50Hz High Pa 30.0 30.0 30.0 30.0 44.0 44.0 44.0
  Air flow rate - 50Hz Cooling At high fan speed m³/min 7.5 8.0 8.0 8.0 10.5 12.5 16.5
      At low fan speed m³/min 6.4 6.4 6.4 6.4 8.5 10.0 13.0
Drain-up height mm 600 600 600 600 600 600 600
Heating capacity Nom. kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0
Current - 50Hz Maximum fuse amps (MFA) A 16 16 16 16 16 16 16
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name   VE VE VE VE VE VE VE
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Notes (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting.
  (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
  (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
  (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%.
  (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA (8) - MCA/MFA: MCA = 1.25 x FLA
  (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA (9) - MFA ≤ 4 x FLA
  (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases (10) - Contains fluorinated greenhouse gases
  (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker (11) - Instead of a fuse, use a circuit breaker
  (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA (12) - Select wire size based on the value of MCA
  (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A (13) - Next lower standard fuse rating minimum 15A