Specifications Table for FTX-GV / RX-GV

FTX20GV1B / RX20GV1B FTX25GV1B / RX25GV1B FTX35GV1B / RX35GV1B FTX50GV1B / RX50G2V1B FTX50GV1B / RX50G3V1B FTX60GV1B / RX60G2V1B FTX60GV1B / RX60G3V1B FTX71GV1B / RX71GV1B FTX71GV1B / RX71GV1B9
Cooling capacity Min. kW 1.3 1.3 1.3 1.7 1.7 1.7 1.7 2.3 2.3
  Nom. kW 2.0 (3) 2.5 (3) 3.2 (3) 5.0 (3) 5.0 (2) 6.0 (3) 6.0 (2) 7.1 (3) 7.1 (2)
  Max. kW 2.6 3.0 3.8 6.0 6.0 6.7 6.7 8.5 8.5
Heating capacity Min. kW 1.3 1.3 1.3 1.7 1.7 1.7 1.7 2.3 2.3
  Nom. kW 2.5 (4) 2.8 (4) 3.4 (4) 5.8 (4) 5.8 (3) 7.0 (4) 7.0 (3) 8.2 (4) 8.2 (3)
  Max. kW 3.5 4.0 4.8 7.7 7.7 8.0 8.0 10.2 10.2
Nominal efficiency EER   3.62 3.38 3.37 3.23 3.23 3.02 3.02 3.02 3.02
  COP   3.90 3.68 3.74 3.63 3.63 3.43 3.43 3.22 3.22
  Annual energy consumption kWh 275 370 470 775 775 995 995 1,175 1,175
  Energy labeling Directive Cooling   A A A A A B B B B
    Heating   A A A A A B B C C
Space cooling Capacity Pdesign kW         5.00   6.00   7.10
  Energy efficiency class         A+   A   B
  SEER         5.63   5.10   4.93
  Annual energy consumption kWh/a         311   412   504
Space heating (Average climate) Capacity Pdesign kW         4.60   4.80   6.50
  Energy efficiency class         A+   A   A
  SCOP/A         4.08   3.74   3.50
  Annual energy consumption kWh/a         1,578   1,795   2,593
Piping connections Drain OD mm       18.0 18.0 18.0 18.0 18.0 18.0
  Gas OD mm       12.7 12.7 12.70 12.70 15.9 15.9
  Liquid OD mm       6.35 6.35 6.35 6.35 6.35 6.35
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal)
  (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB, outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m. High fan speed indoor unit (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB, outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m. High fan speed indoor unit (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB, outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m. High fan speed indoor unit (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB, outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m. High fan speed indoor unit (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load