Specifications Table for FCQG-F / RQ-BV3

FCQG71FVEB / RQ71B8V3B FCQG100FVEB / RQ100B8V3B
Cooling capacity Nom. kW 7.1 (3) 10.0 (3)
Heating capacity Nom. kW 8.0 (4) 11.2 (4)
Nominal efficiency EER   2.64 2.61
  COP   2.84 2.99
  Annual energy consumption kWh 1,345 1,915
  Energy labeling Directive Cooling   D D
    Heating   D D
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load