Specifications Table for ATXF-A / ARXF-A

ATXF20A5V1B / ARXF20A5V1B ATXF25A5V1B / ARXF25A5V1B ATXF35A5V1B / ARXF35A5V1B ATXF50A2V1B / ARXF50A2V1B ATXF50A2V1B / ARXF50A5V1B ATXF60A2V1B / ARXF60A2V1B ATXF60A2V1B / ARXF60A5V1B ATXF71A2V1B / ARXF71A5V1B ATXF71A2V1B / ARXF71A2V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.70 1.70 1.70 1.70 2.30 2.30
  Nom. kW 2.00 2.50 3.30 5.00 5.00 6.00 6.00 7.10 7.10
  Max. kW 2.6 3.0 3.8 6.00 6.00 7.00 7.00 7.30 7.30
Heating capacity Min. kW 1.30 1.30 1.30 1.70 1.70 1.70 1.70 2.30 2.30
  Nom. kW 2.50 2.80 3.50 6.00 6.00 6.40 6.40 8.20 8.20
  Max. kW 3.50 4.00 4.80 7.70 7.70 8.00 8.00 9.00 9.00
Nominal efficiency Annual energy consumption kWh       758 758 923 923 1,403 1,403
  COP   4.16 3.98 3.98 3.71 3.71 3.90 3.90 3.12 3.12
  EER   3.91 3.27 3.27 3.30 3.30 3.25 3.25 2.53 2.53
  Energy labeling Directive Cooling   A A A A A A A E E
    Heating   A A A A A A A D D
Space cooling Annual energy consumption kWh/a 114 141 198 283 283 343 343 486 486
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A A
  Capacity Pdesign kW 2.00 2.50 3.50 5.00 5.00 6.00 6.00 7.10 7.10
  SEER   6.12 6.19 6.18 6.18 6.18 6.12 6.12 5.12 5.12
Space heating (Average climate) Annual energy consumption kWh/a 756 831 972 1,598 1,598 1,670 1,670 2,278 2,278
  Capacity Pdesign kW 2.20 2.40 2.80 4.60 4.60 4.80 4.80 6.20 6.20
  Energy efficiency class   A+ A+ A+ A+ A+ A+ A+ A A
  SCOP/A   4.07 4.03 4.03 4.03 4.03 4.03 4.03 3.81 3.81
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.            
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.            
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data