Specifications Table for SEHVX-AAW / SERHQ-AAW1

SEHVX020AAW / SERHQ020AAW1 SEHVX20AAW / SERHQ020AAW1 SEHVX032AAW / SERHQ032AAW1 SEHVX32AAW / SERHQ032AAW1 SEHVX040AAW / SERHQ020AAW1+SERHQ020AAW1 SEHVX40AAW / SERHQ020AAW1+SERHQ020AAW1 SEHVX064AAW / SERHQ032AAW1+SERHQ032AAW1 SEHVX64AAW / SERHQ032AAW1+SERHQ032AAW1
Cooling capacity Nom. kW 20.7 (1) 20.7 (3) 30.9 (1) 30.9 (3) 41.5 (1) 41.5 (3) 62.3 (1) 62.3 (3)
  Max. kW 24.7 (1) 24.7 (3) 36.9 (1) 36.9 (3) 49.5 (1) 49.5 (3) 74.3 (1) 74.3 (3)
Heating capacity Nom. kW 21.3 (2), 21.3 (3) 21.3 (1), 21.3 (2) 32.1 (2), 32.1 (3) 32.1 (1), 32.1 (2) 42.5 (2), 42.5 (3) 42.5 (1), 42.5 (2) 63.7 (2), 63.7 (3) 63.7 (1), 63.7 (2)
  Max. kW 25.3 (2), 25.3 (3) 25.3 (1), 25.3 (2) 38.1 (2), 38.1 (3) 38.1 (1), 38.1 (2) 50.5 (2), 50.5 (3) 50.5 (1), 50.5 (2) 75.7 (2), 75.7 (3) 75.7 (1), 75.7 (2)
Power input Heating Nom. kW 6.12 (2), 7.44 (3) 6.12 (1), 7.44 (2) 8.72 (2), 11.1 (3) 8.72 (1), 11.1 (2) 12.0 (2), 14.7 (3) 12.0 (1), 14.7 (2) 16.9 (2), 21.7 (3) 16.9 (1), 21.7 (2)
  Cooling Nom. kW 7.59 (1) 7.59 (3) 13.5 (1) 13.5 (3) 15.4 (1) 15.4 (3) 27.4 (1) 27.4 (3)
Cop 4.18   3.62   4.24   3.78  
Notes Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C  
COP   2.86 (2), 3.48 (1)   2.89 (2), 3.68 (1)   2.89 (2), 3.54 (1)   2.94 (2), 3.77 (1)
EER   2.73 (3)   2.29 (3)   2.69 (3)   2.27 (3)
ESEER   4.18   3.62   4.24   3.78
General Supplier/Manufacturer details Name and address     Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name or trademark     Daikin Europe N.V.   Daikin Europe N.V.   Daikin Europe N.V.   Daikin Europe N.V.
  Product description Air-to-water heat pump     Yes   Yes   Yes   Yes
    Brine-to-water heat pump     No   No   No   No
    Heat pump combination heater     No   No   No   No
    Low-temperature heat pump     Yes   Yes   Yes   Yes
    Supplementary heater integrated     No   No   No   No
    Water-to-water heat pump     No   No   No   No
Sound condition Ecodesign and energy label   Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825   Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825   Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825   Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h   11,100   14,000   22,200   28,000
  Other Capacity control     Inverter   Inverter   Inverter   Inverter
    Cdh (Degradation heating)     1.00   1.00   1.00   1.00
    Pck (Crankcase heater mode) kW   0.096   0.099   0.192   0.198
    Poff (Off mode) kW   0.078   0.025   0.154   0.050
    Psb (Standby mode) kW   0.078   0.117   0.154   0.234
    Pto (Thermostat off) kW   0.226   0.359   0.452   0.718
  Integrated supplementary heater NOx emission mg/kWh   0.00   0.00   0.00   0.00
    Psup kW   0.00   0.00   0.00   0.00
    Type of energy input     Electrical   Electrical   Electrical   Electrical
Space heating Average climate water outlet 35°C General SCOP     3.22   3.06   3.22   3.05
      Annual energy consumption kWh   13,600   21,600   27,100   48,400
      Ƞs (Seasonal space heating efficiency) %   126   119   126   120
      Prated at -10°C kW   21.3   32.1   42.4   71.8
      Qhe Annual energy consumption (GCV) Gj   49.0   77.8   97.4   174
      Seasonal space heating eff. class     A+   A   A+   A
    A Condition (-7°CDB/-8°CWB) COPd     2.28   2.09   2.28   2.09
      Pdh kW   17.4   25.3   34.3   59.5
      PERd %   91.2   83.6   91.2   83.6
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)     1.00   1.00   1.00   1.00
      COPd     3.32   2.99   3.32   2.99
      Pdh kW   10.9   17.3   22.8   38.7
      PERd %   133   120   133   120
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)     1.00   1.00   1.00   1.00
      COPd     3.84   3.95   3.84   3.95
      Pdh kW   7.20   11.1   14.7   24.9
      PERd %   154   158   154   158
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)     1.00   1.00   1.00   1.00
      COPd     4.08   4.60   4.08   4.60
      Pdh kW   5.80   5.30   12.7   23.9
      PERd %   163   184   163   184
    Tol (temperature operating limit) COPd     1.97   1.86   1.97   1.86
      Pdh kW   17.4   23.3   32.7   56.2
      PERd %   78.8   74.4   78.8   74.4
      TOL °C   -10.0   -10.0   -10.0   -10.0
      WTOL °C   35.0   35.0   35.0   35.0
    Tbiv (bivalent temperature) COPd     2.28   2.15   2.28   2.15
      Pdh kW   17.4   27.2   34.3   60.8
      PERd %   91.2   86.0   91.2   86.0
      Tbiv °C   -7.00   -6.00   -7.00   -6.00
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW   3.90   8.80   3.20   5.00
  Cold climate water outlet 35°C General Annual energy consumption kWh   15,900   26,300   27,500   44,200
      Ƞs (Seasonal space heating efficiency) %   101   105   103   112
      Prated at -22°C kW   16.9   28.8   29.7   51.6
      Qhe Annual energy consumption (GCV) Gj   57.2   94.4   99.1   159
  Warm climate water outlet 35°C General Annual energy consumption kWh   7,190   11,200   14,400   19,700
      Ƞs (Seasonal space heating efficiency) %   145   142   145   162
      Prated at 2°C kW   20.6   31.4   41.3   62.9
      Qhe Annual energy consumption (GCV) Gj   25.9   40.4   51.9   71.1
Notes   Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011   Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011   Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011   Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011
    Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C   Heating Ta DB/WB 7/6°C - LWC45°C
    Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011   Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011   Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011   Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011
    Its functioning relies on fluorinated greenhouse gases   Its functioning relies on fluorinated greenhouse gases   Its functioning relies on fluorinated greenhouse gases   Its functioning relies on fluorinated greenhouse gases