Specifications Table for FLXS-B / RXS-L3

FLXS25BAVMB / RXS25L3V1B
Indoor unit FLXS25B
Outdoor unit RXS25L3
Cooling capacity Min. kW 1.2
  Min. Btu/h 4,100
  Min. kcal/h 1,030
  Nom. kW 2.5 (2)
  Nom. Btu/h 8,500 (2)
  Nom. kcal/h 2,150 (2)
  Max. kW 3.0
  Max. Btu/h 10,200
  Max. kcal/h 2,580
Heating capacity Min. kW 1.2
  Min. Btu/h 4,100
  Min. kcal/h 1,030
  Nom. kW 3.4 (2)
  Nom. Btu/h 11,600 (2)
  Nom. kcal/h 2,920 (2)
  Max. kW 4.5
  Max. Btu/h 15,400
  Max. kcal/h 3,870
Power input Cooling Min. kW 0.300
    Nom. kW 0.668 (2)
    Max. kW 0.860
  Heating Min. kW 0.290
    Nom. kW 0.960 (2)
    Max. kW 1.490
Nominal efficiency EER   3.74 (1)
  COP   3.54 (1)
  Annual energy consumption kWh 334
  Energy labeling Directive Cooling   A
    Heating   B
Space cooling Capacity Pdesign kW 2.50
  Energy efficiency class   A
  SEER   5.19
  Annual energy consumption kWh/a 169
  A Condition (35°C - 27/19) Pdc kW 2.50
    EERd   3.74
    Power input kW 0.67
  B Condition (30°C - 27/19) Pdc kW 1.84
    EERd   5.96
    Power input kW 0.31
  C Condition (25°C - 27/19) Pdc kW 1.36
    EERd   8.40
    Power input kW 0.16
  D Condition (20°C - 27/19) Pdc kW 1.44
    EERd   10.56
    Power input kW 0.14
Space heating (Average climate) Capacity Pdesign kW 2.50
  Energy efficiency class   A
  SCOP/A   3.80
  SCOPnet/A   3.87
  Annual energy consumption kWh/a 921
  Required back up heating cap at design conditions kW 0.33
  TOL Tol (temperature operating limit) °C -15
    Pdh (declared heating cap) kW 2.10
    COPd (declared COP)   1.92
    Power input kW 1.09
  TBivalent Tbiv (bivalent temperature) °C -7
    Pdh (declared heating cap) kW 2.21
    COPd (declared COP)   2.33
    Power input kW 0.95
  A Condition (-7°C) Pdh (declared heating cap) kW 2.21
    COPd (declared COP)   2.33
    Power input kW 0.95
  B Condition (2°C) Pdh (declared heating cap) kW 1.35
    COPd (declared COP)   4.02
    Power input kW 0.34
  C Condition (7°C) Pdh (declared heating cap) kW 1.10
    COPd (declared COP)   4.94
    Power input kW 0.22
  D Condition (12°C) Pdh (declared heating cap) kW 1.28
    COPd (declared COP)   6.25
    Power input kW 0.20
Power consumption in other than active mode Crankcase heater mode PCK W 0.0
  Off mode POFF W 14.0
  Standby mode Cooling PSB W 14.0
Pto (Thermostat off) W 70.0
Cooling Cdc (Degradation cooling)   0.25
Heating Cdh (Degradation heating)   0.25
Cooling function included Yes
Heating function included Yes
Average climate included Yes
Cold season included No
Warm season included No
Ecolabel logo No
Moisture removal Cooling l/h 1.2
Piping connections Drain OD mm 18.0
  Gas OD mm 9.5
  Heat insulation   Both liquid and gas pipes
  Liquid OD mm 6.35
Current Nominal running current (RLA) - 50Hz Cooling A 3.80 (3), 3.70 (4), 3.49 (5)
    Heating A 4.70 (3), 4.50 (4), 4.30 (5)
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (3) - 220V
  (4) - 230V
  (5) - 240V