Specifications Table for EKSH-P

EKSH26P1
Mounting Horizontal
Dimensions Packed unit Height mm 1,390
    Width mm 2,100
    Depth mm 110
  Unit Height mm 1,300
    Width mm 2,000
    Depth mm 85
Weight Packed unit kg 45
  Unit kg 42
Volume l 2.1
Packing Material   EPS, Cardboard, Carton, PE wrapping foil
  Weight kg 3
Surface Outer 2.60
  Aperture 2.360
  Absorber 2.36
Coating Micro-therm (absorption max. 96%, Emission ca. 5% +/-2%)
Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Glazing Single pane safety glass, transmission +/- 92%
Insulation material Mineral wool, 50mm
Available mounting system on-/ in-/ flat-roof
Allowed roof angle Min. ° 15
  Max. ° 80
Operating pressure Max. bar 6
Stand still temperature Max. °C 192
General Supplier/Manufacturer details Name or trademark   Daikin Europe N.V.
    Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
  Product description Model identifier   EKSH26P
Thermal performance collector efficiency (Ƞcol) % 61
  Zero loss collector efficiency Ƞ0 % 0.784
  Heat loss coefficient a1 W/m².K 4.250
  Temperature dependence of the heat loss coefficient a2 W/m².K² 0.007
  Thermal capacity kJ/K 6.5
  Incident angle modifier IAM at 50°   0.94