Specifications Table for ADEQ-C / AZQS-B(8)V1

ADEQ71C2 / AZQS71B2 ADEQ71C2VEB / AZQS71B2V1B ADEQ100C2 / AZQS100B8 ADEQ100C2VEB / AZQS100B8V1B ADEQ125C2 / AZQS125B8 ADEQ125C2VEB / AZQS125B8V1B
Cooling capacity Nom. kW 6.80 (1) 6.80 (1) 9.50 (1) 9.50 (1) 12.1 (1) 12.1 (1)
Heating capacity Nom. kW 7.50 (1) 7.50 (2) 10.8 (1) 10.8 (2) 13.5 (1) 13.5 (2)
Nominal efficiency EER           2.27
Seasonal efficiency (according to EN14825) Cooling Energy efficiency class   A   A      
    Pdesign kW 6.80   9.50      
    SEER   5.40   5.10      
    Annual energy consumption kWh 441   652      
  Heating (Average climate) Energy efficiency class   A   A      
    Pdesign kW 6.00   7.60      
    SCOP/A   3.81   3.81      
    Annual energy consumption kWh 2,205   2,793      
Pto (Thermostat off) W 3.00   4.00      
Pck (Crankcase heater mode) W 0.00   0.00      
Poff (Off mode) W 14.5   22.0      
Notes Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2   Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2   Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2  
  See separate drawing for electrical data   See separate drawing for electrical data   See separate drawing for electrical data  
  Contains fluorinated greenhouse gases   Contains fluorinated greenhouse gases   Contains fluorinated greenhouse gases  
Space cooling Energy efficiency class     A   A    
  Capacity Pdesign kW   6.80   9.50    
  SEER     5.40   5.10    
  Annual energy consumption kWh/a   441   652    
Space heating (Average climate) Energy efficiency class     A   A    
  Capacity Pdesign kW   6.00   7.60    
  SCOP/A     3.81   3.81    
  Annual energy consumption kWh/a   2,205   2,793